CDC之Synchronizers

来源:转载

1 Scenarios

Two scenarios for passing signals across CDC boundaries:

1) sometimes it's not necessary to sample every value, but be sure that the sampled values are accurate. One example is the set of gray

code counters used in asynchronous FIFO. In asynchronous FIFO, synchronized gray code counters do not need to capture every legal value from

the opposite clock domain, but it's critical that sampled values be accurate to recognize when full and empty conditions have occurred.

2) a CDC signal must be properly recognized or recognized & acknowledged before a change occurs.

   In both of these scenarios, the CDC signals will require some form of synchronization into the receiving clock domain.

 

2 Receiving clock domain

1) Two flip-flop synchronizer

For most synchronization applications, the two flip-flop synchronizer is sufficient to remove all likely metastability.

2) Three flip-flop synchronizer

   For some very high speed designs, a third flop is added to increase the MTBF to a satisfactory duration of time.

3 Sending clock domain

 Registering signals in the sending clock domain should generally be required.

4 Example (Verilog)

 1 module sync_cell (

2

3 // OUTPUTs

4 data_out, // Synchronized data output

5

6 // INPUTs

7 clk, // Receiving clock

8 data_in, // Asynchronous data input

9 rst // Receiving reset (active high)

10 );

11

12 // OUTPUTs

13 output data_out; // Synchronized data output

14

15 // INPUTs

16 input clk; // Receiving clock

17 input data_in; // Asynchronous data input

18 input rst; // Receiving reset (active high)

19

20

21 //=================================================

22 // 1) SYNCHRONIZER

23 //=================================================

24

25 reg [1:0] data_sync;

26

27 always @(posedge clk or posedge rst)

28 if (rst) data_sync <= 2'b00;

29 else data_sync <= {data_sync[0], data_in};

30

31 assign data_out = data_sync[1];

32

33

34 endmodule // sync_cell

 